Standard control panel
Standard control panel is the most basic configuration to meet the normal operation and use of the unit. It has the advantages of simple operation, complete functions and reliable protection. The panel has operation buttons such as power on, preheating, startup, shutdown (emergency shutdown). When a fault alarm occurs, the control panel will issue a corresponding fault light (sound) alarm when the control unit is shut down.
Unit operating parameters detection instructions:
Power generation three phase voltage
Power generation three phase current
Generation frequency
Coolant temperature
Operation time
Control and protection function
High water temperature
Low oil pressure
Overspeed
Battery charging failure
Emergency shutdown and other protection
Automatic control system generator set
1. manual control panel
Provide basic start / stop function of unit.
And has the following basic configuration and functions
Start / stop controller
Three phase alternating current meter
Voltmeter and selector switch
Frequency meter / water temperature gauge / oil pressure gauge / schedule / battery voltmeter / emergency stop button
Alarm function: overspeed, high water temperature, low oil pressure, charging failure.
Protection function: low oil pressure, high water temperature, overspeed, emergency shutdown and other preset protection.
2. no power supply (voltage loss) self starting control panel.
The control eliminates the standard manual control panel function and configuration, and attaches the remote control interface.
Automatic / stop / manual function selection
Starting delay relay (1~5 seconds, adjustable)
Shutdown delay relay (0~270 sec, adjustable)
3. self starting time relay
Electric charger
Alarm Indicators Increased: Low/Overspeed, Output Voltage Failure, Start Failure, High Water Level Forecast Alarm, Emergency Stop
Protection function increases: low / over speed, starter failure, output hardness fault (overvoltage, undervoltage, overcurrent).
Automatic remote monitoring control panel
LCD displays the operation steps, status, faults and parameters of the unit.
With R232 or 485 interface, remote control, telemetry, remote signaling function.
Unit protection, automatic shutdown alarm below.
Starting failure, overspeed, low speed, high water temperature, low oil pressure, speed sensor no signal, charging failure, etc.
4. automatic load switching (ATS)
Four-stage mechanical/electrical interlock switch, power supply, power generation, on-load status indicator, automatic/manual selector
The screen is treated by pickling, phosphating and plastic spraying, allowing enough space for input and output cables.
Automatic switching time not exceeding 7 seconds (adjustable)
5. unattended, independent automatic control panel.
Can be applied to the user requirements, provide self-starting control function and automatic load switching function integrated independent control cabinet, easy to operate, suitable for the centralized control of electrical equipment.
6. parallel control panel
Manual/semi-automatic/full-automatic two or more parallel functions, multiple parallel into the grid, more reliable power supply, centralized dispatch, automatic load distribution, can make maintenance, maintenance more convenient, more economical. It can be put into use according to actual load needs, and oil saving will expand more flexible in future. According to the needs of development, equipment can be increased at any time to meet the increased load.